No matter how busy your schedule is you can access the Silent Knight library of webinars 24/7. From beginner to advanced skill levels, technicians to fire alarm business owners, you will be sure to find a webinar to help you stay up to date on a variety of topics. The webinars are approximately 50 minutes in duration and led by Silent Knight specialist and outside industry professionals. The webinars can be found at https://www.silentknight.com/support/Pages/Webinars.aspx along with registration links for upcoming webinars.

Examples of Webinar Titles:

  • 10 Things Your Insection & Testing Contracts Should Have
  • What’s New in the 2013 Edition of the National Fire Alarm Signaling Code – NFPA 72
  • A Fire Alarm with a Powerful Voice! 5820XL-EVS
  • CO Codes and Detection: SK-FIRE-CO
  • Silent Knight FAQ’s and Tech Tips
  • 10 Steps to NICET Success

 

About the Author
Loren Schreiber has been with Silent Knight for 27 years and currently holds the position of Product Marketing Manager.  Loren’s primary focus is obtaining customer needs and requirements for new product development.

Elevator Recall Made Easy

NFPA 72 states in facilities without a building fire alarm system, initiating devices used to initiate fire fighters’ service recall shall be connected to a dedicated function fire alarm control unit. Both electrical contractors and fire alarm dealers have found success with the Silent Knight 5700 addressable fire alarm control panel in elevator recall applications. The 5700 has the flexibility to meet national and local codes that may differ from locality to locality. It is important you become familiar with the version of the various standards that have been adopted locally and how your AHJ interprets the code.

The 5700 can perform the following elevator recall functions

  • Elevator “Capture” to Primary or Alternative Floor
  • Elevator “Shunt Trip”
  • Cab Lamp Activation
  • Addressable Heat and Smoke Detectors for applications with sprinkler heads at the top of the hoist way and/or elevator machine room
  • 2-Count Feature – Two detectors on the same floor must activate before recall is initiated

Up to 50 detectors (smokes/heats) and 50 modules (relays) can be connected to the 5700 using System Sensor protocol.

5700ERdrawing